Abstract
Background and Objective
Extended-release (ER) opioids are associated with high rates of abuse. Recreational opioid users often manipulate ER formulations to achieve a high plasma concentration in a short amount of time, resulting in a more rapid and intense high. Patients may also manipulate ER tablets to facilitate swallowing, without recognizing that manipulation could increase release rate. The goal of this study was to assess the ability of oxycodone DETERx (Xtampza® ER, Collegium Pharmaceutical, Inc., Canton, MA, USA) and other commercially available ER opioid formulations with and without physicochemical abuse-deterrent characteristics to be manipulated by crushing in an in vitro setting.
Methods
In vitro dissolution techniques were used to compare the opioid release from a variety of ER opioid formulations. Dissolution was assessed for intact and crushed dosage forms. Opioid release was quantified using high-performance liquid chromatography.
Results
Intact formulations exhibited drug release rates characteristic of 12- or 24-h dosage forms. After crushing using commonly available household tools, only Xtampza ER maintained ER of opioid.
Conclusions
Xtampza ER maintained its ER characteristics after crushing, unlike many other commercially available opioid formulations, including some formulated with abuse-deterrent properties. As such, Xtampza ER may be less appealing to abusers and offer a margin of safety for patients who manipulate dosage forms to facilitate swallowing.