Alexandros G .Sfakianakis,ENT,Anapafeos 5 Agios Nikolaos Crete 72100 Greece,00302841026182

Πέμπτη 11 Φεβρουαρίου 2021

Complications of Free Flaps for Oromandibular Reconstruction

xlomafota13 shared this article with you from Inoreader

Objectives/Hypothesis

To determine the frequency and management of short‐ and long‐term complications related to oromandibular free flap reconstruction and identify potentially predictive factors of hardware complications.

Study Design

Retrospective chart review.

Methods

A retrospective database from chart review was formed consisting of 266 oromandibular free flap reconstructions performed at a single institution over a 15‐year period. Data were collected on demographics, surgical treatment, complications, and management of complications. Subgroup univariate and multivariate analyses were performed to compare patients with hardware complications and those without.

Results

Eighty‐one of 266 patients (30.5%) that underwent oromandibular reconstruction had an early complication (<4 weeks after surgery), and the most common complications were cervical wound dehiscence (11.3%) and fistulas (9.40%). Eighty of 266 patients (30.1%) had a long‐term complication (>4 weeks after surgery) and the most common complication was plate exposure (26.7%). Univariate and multivariate analyses showed no association between whether there was hardware extrusion and fibula versus scapula, smoking history, virtual surgical planning (VSP), and dental implantation (P > .05). Only early complications (OR, 3.59, 95% CI, 1.83–7.05, P < .01) and patients undergoing oromandibular reconstruction for osteoradionecrosis (OR, 2.26, 95% CI, 1.10–4.64, P = .03) were strongly and independently associated with subsequent hardware extrusion on univariate analysis.

Conclusions

Both short‐ and long‐term complications are common after oromandibular reconstruction. The most important predictive factor for a late complication is an early complication and prior radiation. There was no difference of plate complications among the various free flap types. Dental implantation and use of VSP were not associated with hardware complications.

Level of Evidence

4 Laryngoscope, 2021

View on the web

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Δημοφιλείς αναρτήσεις